The last thing you want is for your AGA to fail. To keep your AGA going, have it regularly serviced. When we service your cooker you can be sure that if any new parts are used they will genuine AGA parts and that the engineer working on your cooker is fully trained and qualified at AGA.
AGA Servicing Procedures
- Visual inspection of oil storage tank
- Inspection of oil line filter and fire valves
- Examination of joints and flue pipes for leakages
- Visual examination of the flue termination
- Cleaning of combustion chamber and flue ways
- Removal of burner and de-coking of carbon
- Inspection and cleaning of oil control valve
- Inspection and adjustment of flow rates
- Burner level checked
- Oil depth checked inside burner
- Inspection and checks of Transformer and thermostat operation
- re-assembly and re-lighting of cooker
- visual check of burner flame
- completion of the OFTEC CD11 service report form.