- Visual inspection of oil storage tank
- Inspection of oil line filter and fire valves
- Examination of joints and flue pipes for leakages
- Visual examination of the flue termination
- Inspection and cleaning of heat exchanger
- Inspection and cleaning of secondary exchanger (condensing appliances only)
- Inspection of condensate discharge pipe (condensing appliances only)
- Cleaning of combustion chamber
- Cleaning of photo cell and verifying electrodes are set correctly
- Inspection of fan and motor
- Replacement nozzle
- Visual inspection of flexible oil lines and oil pump
- Smoke and pressure testing to identify cleanliness of combustion
- Full electronic combustion analysis check (print out included)
- Pressure check @ fuel pump
- Completion of the OFTEC CD/11 service report form
A boiler service will take between 1hr-2hr depending on the make/model of boiler.